36 research outputs found

    Design and Analysis of Conformal Antenna for Future Public Safety Communications: Enabling Future Public Safety Communication Infrastructure

    Get PDF
    Future 4G wireless communication systems include, in their capabilities portfolio, emergency-specific needs, such as data support, broadband communication, and extremely high reliability. An emergency situation can be addressed with undoubtedly more chances of success if augmented information is enabled within the public safety communication novel capabilities. In this article, for a fully augmented information provision based on broadband transmission, a user-end (UE) communication-capabilities enhancement is addressed by deploying multiple antennas without compromising the portability and light weight of first-responder equipment. With this aim, we propose the design of a 4.9-GHz conformal antenna array at the rescuer side (integrated in a helmet) and evaluate its performance in terms of relative data rate gain. The conformal array design is based on traditional patch antennas that consider the need for deployment over an ellipsoidal surface. The antenna array is simulated and then built, and several parameter characterizations (bandwidth, radiation pattern, reflection coefficient, and MC) and measurements are undertaken to ensure the suitability of the design. Furthermore, an analysis of the specific absorption rate (SAR) is performed to guarantee that the exposure to electromagnetic fields is below the standardized levels.The authors would like to thank Prof. Eva Rajo-Iglesias from Universidad Carlos III de Madrid. This work has been partly funded by the Spanish Government through projects CIES (RTC-2015-4213-7), MIMOTEX (TEC2014-61776-EXP) and TERESAADA (TEC2017-90093-C3-2-R) (MINECO/AEI/FEDER, UE

    Family physician and endocrinologist coordination as the basis for diabetes care in clinical practice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To estimate the proportion of diabetic patients (DPts) with peripheral vascular disease treated at a primary health care site after an endocrinologist-based intervention, who meet ATP III and Steno targets of metabolic control, as well as to compare the outcome with the results of the patients treated by endocrinologists.</p> <p>Methods</p> <p>A controlled, prospective over 30-months period study was conducted in area 7 of Madrid. One hundred twenty six eligible diabetic patients diagnosed as having peripheral vascular disease between January 2003 and June 2004 were included in the study. After a treatment period of three months by the Diabetes team at St Carlos Hospital, 63 patients were randomly assigned to continue their follow up by diabetes team (Group A) and other 63 to be treated by the family physicians (FP) at primary care level with continuous diabetes team coordination (Group B). 57 DPts from Group A and 59 from Group B, completed the 30 months follow-up period. At baseline both groups were similar in age, weight, time from diagnosis and metabolic control. The main outcomes of this study were the proportion of patients meeting ATP III and Steno goals for HbA1c (%), Cholesterol, HDL cholesterol, LDL cholesterol, triglycerides, blood pressure, albumine-to-creatinine excretion ratio (ACR), body mass index (BMI), waist circumference (WC), anti-aggregation treatment and smoking status.</p> <p>Results</p> <p>At the end of the follow up, no differences were found between the groups. More than 37% of diabetic patients assigned to be treated by FP achieved a HbA1c < 6.5%, more than 50% a ACR < 30 mg/g, and more than 80% reached low risk values for cholesterol, LDL cholesterol, triglycerides, diastolic blood pressure and were anti-aggregated, and 12% remained smokers. In contrast, less than 45% achieved a systolic blood pressure < 130 mm Hg, less than 12% had a BMI < 25 Kg.m-2 (versus 23% in group A; p < 0.05) and 49%/30% (men/women) had a waist circumference of low risk.</p> <p>Conclusion</p> <p>Improvements in metabolic control among diabetic patients with peripheral vascular disease treated at a primary health care setting is possible, reaching similar results to the patients treated at a specialized level. Despite such an improvement, body weight control remains more than poor in both levels, mainly at primary care level. General practitioner and endocrinologist coordination care may be important to enhance diabetes management in primary care settings.</p> <p>Trial registration</p> <p>Clinical Trial number ISRCTN75037597</p

    Improved functionalization of oleic acid-coated iron oxide nanoparticles for biomedical applications

    Get PDF
    Superparamagnetic iron oxide nanoparticles can providemultiple benefits for biomedical applications in aqueous environments such asmagnetic separation or magnetic resonance imaging. To increase the colloidal stability and allow subsequent reactions, the introduction of hydrophilic functional groups onto the particles’ surface is essential. During this process, the original coating is exchanged by preferably covalently bonded ligands such as trialkoxysilanes. The duration of the silane exchange reaction, which commonly takes more than 24 h, is an important drawback for this approach. In this paper, we present a novel method, which introduces ultrasonication as an energy source to dramatically accelerate this process, resulting in high-quality waterdispersible nanoparticles around 10 nmin size. To prove the generic character, different functional groups were introduced on the surface including polyethylene glycol chains, carboxylic acid, amine, and thiol groups. Their colloidal stability in various aqueous buffer solutions as well as human plasma and serum was investigated to allow implementation in biomedical and sensing applications.status: publishe

    Antiinflammatory Therapy with Canakinumab for Atherosclerotic Disease

    Get PDF
    Background: Experimental and clinical data suggest that reducing inflammation without affecting lipid levels may reduce the risk of cardiovascular disease. Yet, the inflammatory hypothesis of atherothrombosis has remained unproved. Methods: We conducted a randomized, double-blind trial of canakinumab, a therapeutic monoclonal antibody targeting interleukin-1β, involving 10,061 patients with previous myocardial infarction and a high-sensitivity C-reactive protein level of 2 mg or more per liter. The trial compared three doses of canakinumab (50 mg, 150 mg, and 300 mg, administered subcutaneously every 3 months) with placebo. The primary efficacy end point was nonfatal myocardial infarction, nonfatal stroke, or cardiovascular death. RESULTS: At 48 months, the median reduction from baseline in the high-sensitivity C-reactive protein level was 26 percentage points greater in the group that received the 50-mg dose of canakinumab, 37 percentage points greater in the 150-mg group, and 41 percentage points greater in the 300-mg group than in the placebo group. Canakinumab did not reduce lipid levels from baseline. At a median follow-up of 3.7 years, the incidence rate for the primary end point was 4.50 events per 100 person-years in the placebo group, 4.11 events per 100 person-years in the 50-mg group, 3.86 events per 100 person-years in the 150-mg group, and 3.90 events per 100 person-years in the 300-mg group. The hazard ratios as compared with placebo were as follows: in the 50-mg group, 0.93 (95% confidence interval [CI], 0.80 to 1.07; P = 0.30); in the 150-mg group, 0.85 (95% CI, 0.74 to 0.98; P = 0.021); and in the 300-mg group, 0.86 (95% CI, 0.75 to 0.99; P = 0.031). The 150-mg dose, but not the other doses, met the prespecified multiplicity-adjusted threshold for statistical significance for the primary end point and the secondary end point that additionally included hospitalization for unstable angina that led to urgent revascularization (hazard ratio vs. placebo, 0.83; 95% CI, 0.73 to 0.95; P = 0.005). Canakinumab was associated with a higher incidence of fatal infection than was placebo. There was no significant difference in all-cause mortality (hazard ratio for all canakinumab doses vs. placebo, 0.94; 95% CI, 0.83 to 1.06; P = 0.31). Conclusions: Antiinflammatory therapy targeting the interleukin-1β innate immunity pathway with canakinumab at a dose of 150 mg every 3 months led to a significantly lower rate of recurrent cardiovascular events than placebo, independent of lipid-level lowering. (Funded by Novartis; CANTOS ClinicalTrials.gov number, NCT01327846.

    Optimisation of Perioperative Cardiovascular Management to Improve Surgical Outcome II (OPTIMISE II) trial: study protocol for a multicentre international trial of cardiac output-guided fluid therapy with low-dose inotrope infusion compared with usual care in patients undergoing major elective gastrointestinal surgery.

    Get PDF
    INTRODUCTION: Postoperative morbidity and mortality in older patients with comorbidities undergoing gastrointestinal surgery are a major burden on healthcare systems. Infections after surgery are common in such patients, prolonging hospitalisation and reducing postoperative short-term and long-term survival. Optimal management of perioperative intravenous fluids and inotropic drugs may reduce infection rates and improve outcomes from surgery. Previous small trials of cardiac-output-guided haemodynamic therapy algorithms suggested a modest reduction in postoperative morbidity. A large definitive trial is needed to confirm or refute this and inform widespread clinical practice. METHODS: The Optimisation of Perioperative Cardiovascular Management to Improve Surgical Outcome II (OPTIMISE II) trial is a multicentre, international, parallel group, open, randomised controlled trial. 2502 high-risk patients undergoing major elective gastrointestinal surgery will be randomly allocated in a 1:1 ratio using minimisation to minimally invasive cardiac output monitoring to guide protocolised administration of intravenous fluid combined with low-dose inotrope infusion, or usual care. The trial intervention will be carried out during and for 4 hours after surgery. The primary outcome is postoperative infection of Clavien-Dindo grade II or higher within 30 days of randomisation. Participants and those delivering the intervention will not be blinded to treatment allocation; however, outcome assessors will be blinded when feasible. Participant recruitment started in January 2017 and is scheduled to last 3 years, within 50 hospitals worldwide. ETHICS/DISSEMINATION: The OPTIMISE II trial has been approved by the UK National Research Ethics Service and has been approved by responsible ethics committees in all participating countries. The findings will be disseminated through publication in a widely accessible peer-reviewed scientific journal. TRIAL REGISTRATION NUMBER: ISRCTN39653756.The OPTIMISE II trial is supported by Edwards Lifesciences (Irvine, CA) and the UK National Institute for Health Research through RMP’s NIHR Professorship

    Omecamtiv mecarbil in chronic heart failure with reduced ejection fraction, GALACTIC‐HF: baseline characteristics and comparison with contemporary clinical trials

    Get PDF
    Aims: The safety and efficacy of the novel selective cardiac myosin activator, omecamtiv mecarbil, in patients with heart failure with reduced ejection fraction (HFrEF) is tested in the Global Approach to Lowering Adverse Cardiac outcomes Through Improving Contractility in Heart Failure (GALACTIC‐HF) trial. Here we describe the baseline characteristics of participants in GALACTIC‐HF and how these compare with other contemporary trials. Methods and Results: Adults with established HFrEF, New York Heart Association functional class (NYHA) ≥ II, EF ≤35%, elevated natriuretic peptides and either current hospitalization for HF or history of hospitalization/ emergency department visit for HF within a year were randomized to either placebo or omecamtiv mecarbil (pharmacokinetic‐guided dosing: 25, 37.5 or 50 mg bid). 8256 patients [male (79%), non‐white (22%), mean age 65 years] were enrolled with a mean EF 27%, ischemic etiology in 54%, NYHA II 53% and III/IV 47%, and median NT‐proBNP 1971 pg/mL. HF therapies at baseline were among the most effectively employed in contemporary HF trials. GALACTIC‐HF randomized patients representative of recent HF registries and trials with substantial numbers of patients also having characteristics understudied in previous trials including more from North America (n = 1386), enrolled as inpatients (n = 2084), systolic blood pressure &lt; 100 mmHg (n = 1127), estimated glomerular filtration rate &lt; 30 mL/min/1.73 m2 (n = 528), and treated with sacubitril‐valsartan at baseline (n = 1594). Conclusions: GALACTIC‐HF enrolled a well‐treated, high‐risk population from both inpatient and outpatient settings, which will provide a definitive evaluation of the efficacy and safety of this novel therapy, as well as informing its potential future implementation

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Dimensioning Method for Conversational Video Applications in Wireless Convergent Networks

    No full text
    New convergent services are becoming possible, thanks to the expansion of IP networks based on the availability of innovative advanced coding formats such as H.264, which reduce network bandwidth requirements providing good video quality, and the rapid growth in the supply of dual-mode WiFi cellular terminals. This paper provides, first, a comprehensive subject overview as several technologies are involved, such as medium access protocol in IEEE802.11, H.264 advanced video coding standards, and conversational application characterization and recommendations. Second, the paper presents a new and simple dimensioning model of conversational video over wireless LAN. WLAN is addressed under the optimal network throughput and the perspective of video quality. The maximum number of simultaneous users resulting from throughput is limited by the collisions taking place in the shared medium with the statistical contention protocol. The video quality is conditioned by the packet loss in the contention protocol. Both approaches are analyzed within the scope of the advanced video codecs used in conversational video over IP, to conclude that conversational video dimensioning based on network throughput is not enough to ensure a satisfactory user experience, and video quality has to be taken also into account. Finally, the proposed model has been applied to a real-office scenario

    Diseño de un plan piloto posconsumo para las pilas botón en las relojerías de la ciudad de Villavicencio

    No full text
    El diseño del plan piloto posconsumo de pilas botón fue el resultado de una investigación llevada a cabo en la ciudad de Villavicencio, que tuvo en cuenta 30 relojerías que fueron encuestadas con el fin de determinar el estado del arte de la Gestión integral de las pilas botón como un residuo de aparatos eléctricos y electrónicos. Según el diagnóstico obtenido, ninguno de los comerciantes encuestados conoce la normatividad actual vigente sobre el tema de pilas botón como RAEE y por tanto son manejadas como un residuo sólido común.Trabajo de grado presentado como requisito para optar el titulo de ingeniero ambiental.PregradoIngeniero(a) Ambienta

    Dimensioning Method for Conversational Video Applications in Wireless Convergent Networks

    No full text
    Abstract New convergent services are becoming possible, thanks to the expansion of IP networks based on the availability of innovative advanced coding formats such as H.264, which reduce network bandwidth requirements providing good video quality, and the rapid growth in the supply of dual-mode WiFi cellular terminals. This paper provides, first, a comprehensive subject overview as several technologies are involved, such as medium access protocol in IEEE802.11, H.264 advanced video coding standards, and conversational application characterization and recommendations. Second, the paper presents a new and simple dimensioning model of conversational video over wireless LAN. WLAN is addressed under the optimal network throughput and the perspective of video quality. The maximum number of simultaneous users resulting from throughput is limited by the collisions taking place in the shared medium with the statistical contention protocol. The video quality is conditioned by the packet loss in the contention protocol. Both approaches are analyzed within the scope of the advanced video codecs used in conversational video over IP, to conclude that conversational video dimensioning based on network throughput is not enough to ensure a satisfactory user experience, and video quality has to be taken also into account. Finally, the proposed model has been applied to a real-office scenario.</p
    corecore